Model CS/CU-RZ71VKR
Cooling Capacity (kW)

7.10 (1.70~8.10)

Heating Capacity (kW)

7.50 (1.70~9.90)

Air Flow (L/s)

369

400

Dehumid (L/h) 4.1
Running Current (A)

9.70

8.80

Power Input (kW)

2.19 (0.45~2.67)

2.06 (0.40~2.85)

AEER/EER (W/W)

ACOP/COP (W/W)

3.22/3.24

3.62/3.64

Star Rating

1.5

2.5

Inside Sound Pressure Level (dB) (Hi/Lo/S-Lo)

49/37/34

49/37/34

Outside Sound Pressure Level (dB) (Hi/S-Lo)

52/47

54/49

Sound Power Level (dB) (Hi/S-Lo)

66/61

68/63

Net Weight - Indoor (Outdoor) 13kg (50kg)
Dimensions - Indoor (Outdoor) (h x w x d)

302 x 1102 x 244mm

(695 x 875 x 320mm)

Refrigerant Pipe Diameter - Liquid Side (mm/(in))

6.35

(1/4)

Refrigerant Pipe Diameter - Gas Side (mm/(in))

15.88

(5/8)

Pipe Extension Length Min~Max (m) 3~30
Pipe Length for Additional Gas (m) 10
Additional Gas Amount (g/m) 25
Power Supply Outdoor
Operating Range (Outdoor) - Cooling (°C) +5~+46
Operating Range (Outdoor) - Heating (°C) -15~+24
Refrigerant Type R32